Home / Products / Above-ground fuel / Fireguard® 4-hour fire-rated tanks

Tank Solutions – Fuel

Fireguard® 4-hour fire-rated tanks

A double-wall, fire-protected above-ground steel tank with lightweight thermal insulation between the inner and outer tanks, rated to the SwRI 4-hour fire test.

Get a price

Tell us roughly what you need. A sales engineer for your state replies within 2 business days.

Have drawings or a full spec? Use the detailed quote form, or call NSW +61 2 4964 8270 or WA +61 8 9434 1707.

By sending you agree to our Privacy Policy.

What it is

Fireguard® 4-hour tanks have an inner and an outer steel tank with a lightweight thermal insulation material between them. The insulation is 75% lighter than concrete, which cuts shipping, installation and relocation costs.

The double wall acts as the bund, so there are no earthen or concrete bunds to build and no rainwater to catch and dispose of. The 4-hour rated model can reduce separation distances by as much as 50%, freeing up more of the site. Work out the ground it frees on your site.

Typical applications

  • Sites where separation distances limit where a tank can go
  • Fleet and transport depots
  • Standby generator fuel
  • Sites where the tank may need to move later
4,900L Fireguard® 4-hour self-bunded diesel tank at the factory
4,900L Fireguard® 4-hour self-bunded diesel tank at the factory
Installed Fireguard® 4-hour steel diesel tank with caged ladder and platform
Installed Fireguard® 4-hour steel diesel tank with caged ladder and platform

Construction

Inner tankSteel
Outer tankSteel
InsulationLightweight thermal insulation, 75% lighter than concrete
Fire ratingSwRI 4-hour fire test
BundingSelf-bunded; no civil bund required
DimensionsSee datasheet

Standards

  • STI Fireguard®Manufactured under licence from the Steel Tank Institute

Manufactured at our Tomago NSW and Kwinana Beach WA sites, both certified to ISO 9001.

Compatible media

  • Fuels
  • Flammable liquids
  • Combustible liquids

Ask your sales engineer to confirm a specific product.

Need a different size or fit-out?

We build to your spec. Send us the application, capacity and site, and a sales engineer covering your state will reply within 2 business days.

Send us your spec

Australian-made Fireguard® 4‑hour rated tanks or an imported tank

We build Fireguard® 4-hour rated tanks under licence from the Steel Tank Institute at our Tomago NSW and Kwinana Beach WA sites. If you’re comparing one with a tank brought in from overseas, the biggest difference is the warranty.

  • Australian made & owned
  • Protecting your environment
Fireguard® 4-hour rated horizontal steel tank with its Fireguard® plate, installed at a bus depot
A Fireguard® 4-hour rated tank we built, installed at a bus depot

Made by Tank Solutions in Australia

  • Yes:Where it’s builtTomago NSW or Kwinana Beach WA, under our Steel Tank Institute (STI) Fireguard® licence
  • Yes:Registration with STIRegistered with STI through the Warranty Validation Card
  • Yes:Warranty30 years against structural failure and 1 year on materials and workmanship, once registered
  • Yes:Moving the tank laterWe recertify a relocated tank so the warranty carries on
  • Yes:Standards and paperworkBuilt to STI Fireguard®, UL 2085 and AS 1940 requirements, with compliance documentation for your commissioning file

Imported

  • Where it’s builtOverseas
  • No:Registration with STIAn importer can’t register the tank
  • No:WarrantyWithout registration the warranty is void
  • Check:Moving the tank laterAsk who will recertify it
  • Check:Standards and paperworkAsk for the compliance documents your site needs

Don’t risk your critical infrastructure on a tank with no warranty

An importer can’t register a Fireguard® 4-hour rated tank, and without registration its warranty is void.

Hospitals, data centres, mines and defence sites depend on their fuel storage. An imported tank may be cheaper, but that’s because it comes without the warranty.

The warranty on a Fireguard® 4-hour rated tank is only valid once the owner completes the Warranty Validation Card and returns it to STI, within 30 days of installation or 90 days after we ship the tank, whichever comes first. Read the Fireguard® performance warranty (PDF).

Photos

10,000L rectangular 4-hour Fireguard® tank. Drag to turn it, pinch or scroll to zoom.

Related articles

News

T90 Fireguard® 4-hour fuel tanks

Double-wall, fire-protected above-ground steel tanks that are rated to the SwRI 4-hour fire test and can reduce separation distances.

How much ground would a Fireguard® 4-hour tank free on your site?

The ground a Fireguard® 4-hour tank frees up by cutting separation distances, and what it is worth. Open the full calculator

Your tank and site

From the tank drawing or datasheet. Ask us for the size of the Fireguard® tank you're looking at.
From your AS 1940 assessment or consultant, for a standard tank of this size and liquid.
Fireguard® 4-hour tanks can reduce separation distances by as much as 50%. Use the figure your assessment allows.
To see how many bays the freed ground could hold.

The figures above are an example to start from. Replace them with your own.

Result

Send these figures to a sales engineer covering your state. We reply within 2 business days.

Send these specs for a quote

Common questions

Can’t see yours? Call NSW +61 2 4964 8270 or WA +61 8 9434 1707.

The 4-hour rated model can reduce separation distances by as much as 50%, which frees up more of the site for other uses.
No. The double wall acts as the bund, so there are no earthen or concrete bunds to build and no rainwater to catch and dispose of.
The thermal insulation between the inner and outer steel tanks is 75% lighter than concrete, which cuts shipping, installation and relocation costs.
Fireguard® 4-hour tanks are made under licence from the Steel Tank Institute (STI).
Fireguard® is insulated and rated to the SwRI 4-hour fire test. Flameshield® is a double-wall steel tank with interstitial monitoring, accredited to a 2-hour fire test, and comes horizontal or vertical, cylindrical or rectangular.

Request a quote

A few details up front means your quote comes back faster, from the right engineer for your state. We price each tank to your spec, with no obligation, and reply within 2 business days.

1 Your project
Installation
2 Drawings & specs optional
3 About you

We reply within 2 business days. By submitting you agree to our Privacy Policy.

Protected by reCAPTCHA

Send us your spec for a quote

Request a Quote