Home / Products / Underground storage tanks

Tank Solutions – Fuel

Underground fuel storage tanks

Double-wall underground fuel storage tanks (USTs) in fibreglass (FRP) and Glasteel® II steel with FRP containment, for service stations, fleet depots and AdBlue, from 2,000L to 200,000L. We build to your spec, including deeper burial and higher head pressure than standard. Underground tanks are installed by accredited installers. See what AS 1692 covers.

Get a price

Tell us roughly what you need. A sales engineer for your state replies within 2 business days.

Have drawings or a full spec? Use the detailed quote form, or call NSW +61 2 4964 8270 or WA +61 8 9434 1707.

By sending you agree to our Privacy Policy.

What is an underground storage tank?

An underground storage tank (UST) is a tank buried below ground, most often to hold diesel, petrol or AdBlue at a service station, truck stop or depot. Going underground frees up the site above, keeps fuel away from vehicles and the public, and holds the product at a relatively low, stable temperature.

A leak can reach soil and groundwater before anyone sees it. That is why our fuel USTs are double-wall, with the space between the walls monitored for leaks.

Double-wall containment and leak monitoring

A double-wall tank has a primary wall that holds the fuel and a secondary wall around it. If the primary wall ever leaks, the outer wall contains the fuel, and the monitoring on the interstitial space between the walls shows it.

360° secondary containment

The outer wall completely surrounds the primary wall, so a leak is held in the tank instead of reaching groundwater.

Hydrostatic monitoring on FRP

On double-wall FRP tanks, Truchek® keeps the interstitial space filled with brine, and a reservoir on top of the tank holds it at a set level. It gives continuous leak detection, lets the owner do a visual tank tightness test and meets EPA requirements.

Vacuum monitoring on Glasteel® II

Glasteel® II tanks leave the factory with a vacuum gauge fitted to the interstitial space, so the tank’s integrity can be monitored.

No corrosion to manage

Fibreglass doesn’t rust, inside or out. On Glasteel® II the FRP outer wall resists corrosion, so the steel tank needs no cathodic protection.

Separate compartments

Double-wall FRP tanks come with 1 to 4 separate compartments, with integral double internal walls between them.

Fuel compatibility

Double-wall FRP tanks are warranted for petrol, diesel, ethanol blends to E85, biodiesel to B20 and jet fuel at ambient temperature, and are compatible with AdBlue.

Which underground tank do I need?

For fuel, the choice is mostly between a double-wall FRP tank and Glasteel® II, a welded steel tank fully enclosed in an FRP outer wall so the steel never touches soil or groundwater. Both are double-wall and both are installed by accredited installers.

If you needChooseWhy
Full secondary containment for fuel, with no corrosionDouble-wall FRP tank2,000–150,000L to UL 1316 for fibreglass tanks, with Truchek® leak monitoring, up to 4 compartments and a 30-year corrosion warranty.
A steel structural tank with FRP containmentGlasteel® II tank2,000–200,000L under STI licence. The FRP outer wall removes the need for cathodic protection.
A new service station, upgrade or replacementService station tankDouble-wall FRP up to 150,000L to UL 1316, with compartments so several grades share one excavation.
AdBlue storage, alone or beside dieselAdBlue tankKept cool underground, as a stand-alone tank or one compartment of a fuel tank.
A light tank where containment isn’t requiredFRP single-wall tankLighter, delivered complete and quick to install. Holds fuels, AdBlue or water, depending on the application.

Service station USTs

We supply underground tanks for service station new builds, upgrades and replacements of tanks that have passed their serviceable life. A service station tank is double-wall FRP up to 150,000L, built to UL 1316, with compartments so several grades share one tank and one excavation.

What a forecourt usually needs

  • Double-wall tanks with interstitial leak monitoring
  • Separate compartments for unleaded, premium, diesel and AdBlue
  • Tanks rated for ethanol blends and biodiesel
  • FRP risers, with 1,200 mm collars standard on pressure systems
  • Installation and testing by an accredited installer

Pair it with

Australian Standards for underground fuel tanks

The standards that apply to underground fuel tanks, and where our range fits. AS 1692 is written for steel tanks, so fibreglass tanks are built to UL 1316 instead.

AS 4897The design, installation and operation of underground petroleum storage systems. It calls for non-corroding tanks and pipework, secondary containment and overfill protection. Double-wall FRP tanks get a third-party tank test after installation to AS 4897, using USEPA methods.
AS 1940The storage and handling of flammable and combustible liquids. Underground tank venting must comply with Section 5.4. See our AS 1940 guide.
AS 1692Steel tanks for flammable and combustible liquids, above and below ground. Glasteel® II tanks are manufactured to AS 1692 and UL 58. See what AS 1692 covers.
UL 1316Glass-fibre-reinforced plastic underground storage tanks for petroleum products. Our double-wall FRP tanks are manufactured to meet or exceed it.

General information only, not compliance advice. Your state regulator and site engineer set what applies to your site.

Replacing an old underground tank

If your site still runs an older single-wall steel tank, a double-wall replacement adds secondary containment and leak monitoring. Taking the old tank out of service and assessing the site follow your state EPA’s guidance for underground petroleum storage systems (UPSS). Send us the site plan and the grades you store and we’ll build the new tank and compartments to your spec. See what’s involved in replacing a service station tank.

Underground or above-ground?

Underground suits sites where space, traffic and appearance matter, such as service stations and busy depots, and keeps AdBlue cool. An above-ground fuel tank needs no excavation, and a self-bunded tank can be moved later, which suits farms, mines and construction sites.

Watch an underground install

A time-lapse of underground fuel tanks going into a service station, from excavation and shoring to craning the tanks in and backfilling. Each step follows our installation manual.

  • Installed by an accredited installer; a non-accredited install voids the warranty
  • Backfilled and anchored to our installation manuals, including the out-of-hole tie-down system
  • Up to 2.1 m of cover on double-wall FRP; at least 600 mm in a dry hole with no traffic, or 1,000 mm with traffic
  • Double-wall FRP tanks tested by a third party after installation to AS 4897

Photos

Is your old single-wall tank a risk?

Which of the published reasons for replacing an underground fuel tank apply to yours. Open the full quiz

8 questions

1. Is the tank single-wall or double-wall?
2. Steel or fibreglass?
3. Is the space between the walls monitored for leaks? Double-wall tanks only. Skip this for a single-wall tank.
4. Is the site being rebuilt?
5. Do you want more capacity or different grades, AdBlue included?
6. Has the regulator or a site assessment called for replacement?
7. How many fuel grades or products does the tank need to hold?
8. Roughly how old is the tank? Recorded for the quote only. The result doesn't use it.

Result

Send your answers to a sales engineer covering your state. We reply within 2 business days.

Send these specs for a quote

Common questions

Can’t see yours? Call NSW +61 2 4964 8270 or WA +61 8 9434 1707.

A tank buried below ground to store a liquid, most often diesel, petrol or AdBlue at a service station, truck stop or depot. Ours are double-wall fibreglass (FRP) or Glasteel® II steel with an FRP outer wall, so a leak in the inner wall is contained and can be detected.
Through the interstitial space between the two walls. Double-wall FRP tanks use Truchek® hydrostatic monitoring, which fills that space with brine and watches its level in a reservoir on top of the tank, giving continuous leak detection that meets EPA requirements. Glasteel® II tanks have a factory-fitted vacuum gauge on the interstitial space.
The underground petroleum storage system is designed, installed and operated to AS 4897, with venting to AS 1940 Section 5.4. Steel tanks such as Glasteel® II are built to AS 1692 and UL 58, and fibreglass tanks to UL 1316. See what AS 1692 covers.
Double-wall FRP tanks carry a 30-year warranty against failure from internal corrosion, and 30 years against structural failure when a qualified contractor performs and validates the installation. Fibreglass doesn’t rust, so there is no internal or external corrosion to manage.
AS 4897 calls for secondary containment, non-corroding tanks and pipework and overfill protection on underground petroleum storage systems, and state EPAs set the rules for each site. Our double-wall FRP and Glasteel® II tanks give that secondary containment, with monitoring of the interstitial space.
Underground suits service stations and busy depots where space, traffic and appearance matter. Above-ground tanks need no excavation, and a self-bunded tank can be moved later.
It depends on capacity, compartments, burial depth and the site. Send us your spec and we’ll price the tank.
Both give double-wall containment. A double-wall FRP tank is fibreglass inside and out, with Truchek® hydrostatic leak monitoring. Glasteel® II has a welded steel inner wall that carries the structural load and an FRP outer wall that fully encloses the steel, so the steel never touches soil or groundwater and needs no cathodic protection.
Double-wall gives full secondary containment and interstitial monitoring, and is the usual choice for fuel. Where that isn’t needed, such as water or some AdBlue installs, a single-wall FRP tank is lighter and quicker to install.
Yes. Double-wall FRP tanks come with 1 to 4 completely separate compartments, depending on size, so diesel, petrol and AdBlue can share one tank and one excavation.
An accredited installer from our installer directory. An installation by a non-accredited installer voids the warranty.
Double-wall FRP tanks carry 30 years against failure from internal corrosion, and 30 years against structural failure when a qualified contractor performs and validates the installation. Materials and workmanship are covered for 1 year.
A double-wall FRP tank takes up to 2.1 m of cover. The minimum in a dry hole is 600 mm of backfill with no traffic, or 1,000 mm with traffic. We also build to deeper burial and higher head pressure than standard on request.
AdBlue can begin to degrade above 26 °C. Underground it stays at a relatively low, stable temperature. See AdBlue storage tanks.

Send us your spec for a quote

Request a Quote