Data centre diesel storage for backup generation

Above-ground steel fuel tanks built to AS 1940 for standby generator fuel storage, sized to your site's runtime requirement.

Clients include
  • Cummins
  • Penske Australia & New Zealand

Get a price

Tell us roughly what you need. A sales engineer for your state replies within 2 business days.

Have drawings or a full spec? Use the detailed quote form, or call NSW +61 2 4964 8270 or WA +61 8 9434 1707.

By sending you agree to our Privacy Policy.

Diesel storage for standby generation

Our self-bunded above-ground steel tanks are manufactured to AS 1940 (the storage and handling of flammable and combustible liquids), with capacities from 2,000L to 200,000L to match your generator runtime target.

Tanks ship from ISO 9001 sites at Tomago NSW or Kwinana Beach WA, with compliance documentation supplied for your commissioning file. Compare every diesel fuel storage tank we make.

What we supply

  • Bulk generator diesel
  • Generator base tanks
  • Tanks sized to runtime
  • Fire-rated tanks near buildings
  • Underground diesel storage
  • Compliance documents for commissioning
Tank Solutions generator base tank for diesel under a containerised standby generator at a data centre site
A Tank Solutions generator base tank holding diesel under a containerised standby generator on a data centre build.

Fuel storage for Uptime Institute Tier sites

The Uptime Institute Tier Standard: Topology sets the same on-site fuel minimum at every Tier, from Tier I to Tier IV. The site must hold enough fuel to run its engine generators for 12 hours at "N" load, the design load of the data centre.

Storing more than 12 hours is the owner's decision, based on the fuel supply risk at the site. We size tanks to the 12-hour minimum or to a longer runtime target. Send us the generator fuel burn at N load and the hours you need, and we will work out the volume and the number of tanks.

Uptime Institute
“The Tier Standard: Topology requires this 12-hour fuel storage minimum for all Tiers.”
Uptime Institute Journal, Fuel System Design and Reliability, 2014
“Exceeding the 12-hour minimum is an Operational Sustainability issue that requires careful analysis of the risks to the data center energy supply.”
Uptime Institute Journal, Fuel System Design and Reliability, 2014

Standards and support

Standards relevant to this sector

  • AS 1940Storage and handling of flammable and combustible liquids
  • AS 1692Steel tank and vessel construction
  • ISO 9001SAI Global, both manufacturing sites

For your commissioning file

  • Compliance documentation supplied with each tank
  • Capacities from 2,000L to 200,000L
  • Manufactured at Tomago NSW or Kwinana Beach WA
  • Fuel tank datasheets

Sizing to a runtime target

Send us the generator load, runtime target and site, and a sales engineer covering your state will reply within 2 business days.

Work out the storage with our calculator

Send us your spec

Australian-made Fireguard® 4‑hour rated tanks or an imported tank

We build Fireguard® 4-hour rated tanks under licence from the Steel Tank Institute at our Tomago NSW and Kwinana Beach WA sites. If you’re comparing one with a tank brought in from overseas, the biggest difference is the warranty.

  • Australian made & owned
  • Protecting your environment
Fireguard® 4-hour rated horizontal steel tank with its Fireguard® plate, installed at a bus depot
A Fireguard® 4-hour rated tank we built, installed at a bus depot

Made by Tank Solutions in Australia

  • Yes:Where it’s builtTomago NSW or Kwinana Beach WA, under our Steel Tank Institute (STI) Fireguard® licence
  • Yes:Registration with STIRegistered with STI through the Warranty Validation Card
  • Yes:Warranty30 years against structural failure and 1 year on materials and workmanship, once registered
  • Yes:Moving the tank laterWe recertify a relocated tank so the warranty carries on
  • Yes:Standards and paperworkBuilt to STI Fireguard®, UL 2085 and AS 1940 requirements, with compliance documentation for your commissioning file

Imported

  • Where it’s builtOverseas
  • No:Registration with STIAn importer can’t register the tank
  • No:WarrantyWithout registration the warranty is void
  • Check:Moving the tank laterAsk who will recertify it
  • Check:Standards and paperworkAsk for the compliance documents your site needs

Don’t risk your critical infrastructure on a tank with no warranty

An importer can’t register a Fireguard® 4-hour rated tank, and without registration its warranty is void.

Hospitals, data centres, mines and defence sites depend on their fuel storage. An imported tank may be cheaper, but that’s because it comes without the warranty.

The warranty on a Fireguard® 4-hour rated tank is only valid once the owner completes the Warranty Validation Card and returns it to STI, within 30 days of installation or 90 days after we ship the tank, whichever comes first. Read the Fireguard® performance warranty (PDF).

The self-bunded tank in 3D

The double wall is the bund, so there is no concrete bund to build on site, and the tank can be moved later.

Built to AS 1940 and AS 1692, in capacities from 2,000L to 200,000L, with up to 110,000L of diesel in each tank.

See the self-bunded tank

3D model of a 65,000 litre self-bunded steel tank with an access platform, stairs and handrails

Drag to turn it. Self-bunded fuel tank

Diesel tanks for data centres

Fireguard® 4-hour fire-rated tanks where the tank sits close to the building, self-bunded tanks for most other sites, and larger options where the site needs them.

Tank Solutions – Fuel

Fireguard® 4-hour fire-rated tanks

Insulated double-wall steel tank rated to the SwRI 4-hour fire test.

Capacity
On request
Standard
STI Fireguard®
Compatible media
Fuels and other flammable and combustible liquids
Tank Solutions – Fuel

Self-bunded diesel & fuel tanks

Relocatable double-wall steel tank that needs no on-site bund.

Capacity
Up to 55,000L petrol; up to 110,000L diesel
Standard
AS 1940, AS 1692
Compatible media
Diesel, unleaded petrol (ULP) and other Class 3 liquids
Tank Solutions – Fuel

Single-wall horizontal above-ground tanks

Cylindrical steel tank on welded cradles, for use in a concrete bund.

Capacity
2,000–150,000L
Standard
AS 1692 Category 4
Compatible media
Hydrocarbons, chemicals and emulsions; Jet A1 and Avgas with internal lining
Tank Solutions – Fuel

Single-wall vertical above-ground tanks

Vertical steel tanks and silos where footprint matters.

Capacity
See datasheet
Standard
AS 1940 (integral bunds)
Compatible media
Process liquids, heavy viscous liquids and dry powders
Tank Solutions – Fuel

Double-wall fibreglass fuel tanks

Double-wall FRP tank with 360-degree secondary containment.

Capacity
2,000–150,000L
Standard
UL 1316
Compatible media
Petrol, diesel, alcohols and alcohol–petrol blends
Tank Solutions – Fuel

Flameshield® 2-hour fire-rated tanks

Double-wall steel tank with interstitial monitoring, 2-hour fire rated.

Capacity
On request
Standard
UL 142, AS 1692
Compatible media
Fuels, with separate compartments for multiple grades

Which diesel tank do I need?

Start with your runtime target and your site. How close the tank sits to the building and how much ground you have will usually decide it.

If you needChooseWhy
No bund to build, and a tank you can move laterSelf-bunded tankThe double wall is the bund. 1,000–110,000L of diesel, built to AS 1940 and AS 1692.
Less space between the tank and the buildingFireguard® 4-hour tankInsulated double wall that is rated to the SwRI 4-hour fire test and can cut separation distances by up to 50%.
A fire rating with leak monitoringFlameshield® 2-hour tank2-hour fire rated, with interstitial leak monitoring. Horizontal or vertical, cylindrical or rectangular.
Large volumes in a concrete bundSingle-wall horizontal tank2,000–150,000L to AS 1692 Category 4, manifolded side by side.
More storage on a small footprintSingle-wall vertical tankVertical tanks hold more on less ground, with an optional shop-built bund to AS 1940.
Diesel stored undergroundDouble-wall FRP tank2,000–150,000L to UL 1316 for fibreglass tanks, with Truchek® leak monitoring and a 30-year corrosion warranty.

Photos

How much diesel do your generators need?

Diesel your standby generators need for a runtime target at N load, and the tanks that hold it. Open the full calculator

Your generators

Count the generators running to carry the site load. Redundant units on standby (the +1 of N+1) don't burn fuel at N load.
From the generator datasheet's fuel consumption table, at the load each set will run at.
The Uptime Institute minimum is 12 hours at N load for every Tier. Many owners store more.
Fuel below the outlet that can't be drawn, plus the space left empty at the top. Leave blank to see usable fuel only.
Where the tanks go

The figures above are an example to start from. Replace them with your own.

Result

Send these figures to a sales engineer covering your state. We reply within 2 business days.

Send these specs for a quote

Common questions

Can’t see yours? Call NSW +61 2 4964 8270 or WA +61 8 9434 1707.

Self-bunded tanks run from 2,000L to 200,000L, with up to 110,000L of diesel in each tank. For more, single-wall horizontal tanks run to 150,000L each and can be manifolded side by side.
Uptime Institute sets a minimum of 12 hours of on-site fuel at "N" load for every Tier, from Tier I to Tier IV. Many owners store more. Send us the fuel burn at N load and your runtime target, and we will size the tanks to suit.
Yes. Compliance documentation is supplied for your commissioning file, and datasheets are on the Downloads page.
Fireguard® tanks are rated to the SwRI 4-hour fire test and can reduce separation distances by as much as 50%. Flameshield® tanks are accredited to a 2-hour fire test.
Not with a self-bunded tank. Its integral steel bund meets State and Territory requirements.
Yes. A self-bunded tank can be moved to any practical location. If it’s relocated, it needs recertifying to keep the warranty.

Send us your data centre spec for a quote