Home / Industries / Fuel & Industrial Operators

Fuel storage for industrial operators

Tank Solutions supplies above-ground steel and underground fibreglass (FRP) fuel tanks to AS 1940, including STI Fireguard® protected above-ground steel tanks, for fleet depots, terminals and industrial sites.

Clients include
  • Ampol
  • BP
  • Viva Energy
  • 7-Eleven
  • Origin Energy
  • AGL
  • APA Group
  • Cleanaway
  • Cummins
  • Coogee Chemicals

Get a price

Tell us roughly what you need. A sales engineer for your state replies within 2 business days.

Have drawings or a full spec? Use the detailed quote form, or call NSW +61 2 4964 8270 or WA +61 8 9434 1707.

By sending you agree to our Privacy Policy.

Compliant fuel storage, above or below ground

Our self-bunded above-ground steel tanks and underground fibreglass tanks are built to AS 1940 (the storage and handling of flammable and combustible liquids). For above-ground installs that call for a protected tank, we build to the licensed STI Fireguard® steel tank system.

Capacities run from 2,000L to 200,000L in standard ranges, with custom fabrication available for larger or non-standard sites. Every tank is manufactured under ISO 9001 quality control at Tomago NSW or Kwinana Beach WA.

Where our tanks go

  • Fuel depots and distributors
  • Industrial and process sites
  • Fleet and transport yards
  • Service stations
  • Plant and equipment refuelling
  • Several fuel grades in one tank
Fireguard® 4-hour self-bunded steel tanks for IOR strapped to a trailer
Fireguard® 4-hour self-bunded steel tanks for IOR strapped to a trailer

Standards and support

Standards relevant to this sector

  • AS 1940Storage and handling of flammable and combustible liquids
  • AS 1692Steel tank and vessel construction
  • STI Fireguard®Licensed protected above-ground steel tank system (UL 2085)

Built to order in Australia

  • Standard ranges from 2,000L to 200,000L
  • Custom fabrication for larger or non-standard sites
  • ISO 9001 manufacturing at Tomago NSW and Kwinana Beach WA
  • Separate compartments for each fuel grade

Custom sizes and fit-outs

We build to your spec. Send us the fuel, capacity and site, and a sales engineer covering your state will reply within 2 business days.

Send us your spec

Made in Australia or imported

Every tank we sell is built at our own factories in Tomago NSW and Kwinana Beach WA. If you’re comparing a quote for an imported tank, these are the points to check.

  • Australian made & owned
  • Protecting your environment
Installed Fireguard® 4-hour rated steel diesel tank with access ladder beside a telecommunications building
A Fireguard® 4-hour rated diesel tank we built, installed at a telecommunications site

Made by Tank Solutions in Australia

  • Yes:Where it’s builtOur own ISO 9001 sites at Tomago NSW and Kwinana Beach WA
  • Yes:Fireguard® 4-hour rated warrantyRegistered with the Steel Tank Institute (STI), with a 30-year warranty against structural failure
  • Yes:StandardsSteel fuel tanks built to AS 1692, and to AS 1940 where it applies
  • Yes:PaperworkCompliance documentation supplied with each tank for your commissioning file
  • Yes:Moving the tank laterWe recertify relocated Fireguard® 4-hour rated and self-bunded tanks to keep the warranty

Imported

  • Where it’s builtOverseas
  • No:Fireguard® 4-hour rated warrantyAn importer can’t register a Fireguard® 4-hour rated tank, which voids the warranty
  • Check:StandardsAsk which standards it’s built to
  • Check:PaperworkAsk what documentation comes with it
  • Check:Moving the tank laterAsk who will recertify it

Don’t risk your critical infrastructure on a tank with no warranty

An importer can’t register a Fireguard® 4-hour rated tank, and without registration its warranty is void.

Hospitals, data centres, mines and defence sites depend on their fuel storage. An imported tank may be cheaper, but that’s because it comes without the warranty.

For Fireguard® 4-hour rated tanks the warranty is the biggest difference. See Fireguard® 4-hour rated tanks: made in Australia or imported, or read the Fireguard® performance warranty (PDF).

Fuel tanks for industrial sites

Steel tanks above ground, fibreglass and Glasteel® tanks below it.

Tank Solutions – Fuel

Self-bunded diesel & fuel tanks

Relocatable double-wall steel tank that needs no on-site bund.

Capacity
Up to 55,000L petrol; up to 110,000L diesel
Standard
AS 1940, AS 1692
Compatible media
Diesel, unleaded petrol (ULP) and other Class 3 liquids
Tank Solutions – Fuel

Fireguard® 4-hour fire-rated tanks

Insulated double-wall steel tank rated to the SwRI 4-hour fire test.

Capacity
On request
Standard
STI Fireguard®
Compatible media
Fuels and other flammable and combustible liquids
Tank Solutions – Fuel

Single-wall horizontal above-ground tanks

Cylindrical steel tank on welded cradles, for use in a concrete bund.

Capacity
2,000–150,000L
Standard
AS 1692 Category 4
Compatible media
Hydrocarbons, chemicals and emulsions; Jet A1 and Avgas with internal lining
Tank Solutions – Fuel

Double-wall fibreglass fuel tanks

Double-wall FRP tank with 360-degree secondary containment.

Capacity
2,000–150,000L
Standard
UL 1316
Compatible media
Petrol, diesel, alcohols and alcohol–petrol blends
Tank Solutions – Fuel

Glasteel® II underground fuel tanks

A welded mild steel tank with an FRP outer layer that provides secondary containment, leak protection and corrosion resistance.

Capacity
2,000–200,000L
Standard
STI Glasteel® II licence
Compatible media
Fuels including blended fuels, ethanol and biodiesel
Tank Solutions – Fuel

Flameshield® 2-hour fire-rated tanks

Double-wall steel tank with interstitial monitoring, 2-hour fire rated.

Capacity
On request
Standard
UL 142, AS 1692
Compatible media
Fuels, with separate compartments for multiple grades

Which fuel tank do I need?

Start with your site. Whether the tank goes above or below ground, whether you already have a bund, and how close it sits to buildings will usually decide it.

If you needChooseWhy
No bund to build, and a tank you can move laterSelf-bunded tankThe double wall is the bund. Up to 110,000L of diesel or 55,000L of petrol, built to AS 1940 and AS 1692.
Less space between the tank and buildingsFireguard® 4-hour tankInsulated double wall that is rated to the SwRI 4-hour fire test and can cut separation distances by up to 50%.
A fire rating with several fuel gradesFlameshield® 2-hour tank2-hour fire rated, with interstitial leak monitoring and compartments for each grade.
Large volumes in a concrete bundSingle-wall horizontal tank2,000–150,000L to AS 1692 Category 4, manifolded side by side.
Underground storage with full containment and no corrosionDouble-wall FRP tank2,000–150,000L to UL 1316 for fibreglass tanks, with Truchek® leak monitoring and a 30-year corrosion warranty.
A steel structural tank undergroundGlasteel® II tank2,000–200,000L under STI licence. The FRP outer wall removes the need for cathodic protection.

Photos

Which fuel tank fits your site?

Eight quick questions. You get the tank that fits and up to two alternatives, with the reason for each. Open the full quiz

8 questions

1. What will you store?
2. Above or below ground?
3. What kind of site?
4. Do you already have a concrete bund?
5. Might the tank move to another site later?
6. Do separation distances to buildings or boundaries limit where the tank can go?
7. Several fuel grades from one tank?
8. Roughly how much in one tank?

Result

Send your answers to a sales engineer covering your state. We reply within 2 business days.

Send these specs for a quote

Common questions

Can’t see yours? Call NSW +61 2 4964 8270 or WA +61 8 9434 1707.

Above-ground steel tanks are built to AS 1940 and AS 1692, and Fireguard® 4-hour tanks to the licensed STI Fireguard® system (UL 2085). Underground double-wall FRP tanks are built to UL 1316 and AS 1692. See accreditation.
Not with a self-bunded tank. Its integral steel bund meets State and Territory requirements. Single-wall tanks sit in a simple concrete bund.
Fireguard® tanks are rated to the SwRI 4-hour fire test and can reduce separation distances by as much as 50%. Flameshield® tanks are accredited to a 2-hour fire test.
Yes. Self-bunded and Flameshield® 2-hour tanks can be built with separate compartments for each grade, depending on tank size, and double-wall FRP underground tanks take up to 4 compartments.
Above ground is quicker to install and easy to inspect. Underground saves space and suits service stations and busy yards. Compare the options on the above-ground and underground fuel tank pages.
At our own ISO 9001 sites at Tomago NSW and Kwinana Beach WA.

Send us your site spec for a quote